# EICR testing explained: what electrical measurements tell the inspector
By Test Master UK6 November 20262 min read

Service illustration: eicr testingEICR testing combines inspection with appropriate electrical measurements. The readings help a competent inspector assess protective measures and installation condition; they do not provide a simple safety score for a property manager to interpret alone. This guide explains the purpose of common checks, rather than repeating the stages of an inspection visit or providing an electrical testing procedure.

## Continuity and protective conductors
Continuity checks can help establish that relevant conductors are connected as intended. Protective conductors and bonding form part of the installation&#x27;s protection against electric shock. The inspector considers the arrangement, circuit details and results together.

A continuity reading does not prove every other protective measure works. It must be interpreted in context and with the inspection findings. Property managers should not open accessories or attempt to reproduce measurements using a household meter.

## Insulation resistance
Insulation resistance testing can identify concerns with insulation between relevant conductors. The method must take account of connected equipment and the circuit arrangement. A low reading is a reason for competent interpretation, not proof of one specific damaged cable.

Moisture, connected devices and other circumstances may affect results or the appropriate method. The inspector decides how to test safely and records relevant limitations. Generic online thresholds should not be used to approve an installation without that assessment.

## Fault protection, polarity and RCDs
Fault-loop information helps assess whether the protective arrangement can achieve the necessary disconnection under fault conditions. Polarity checks concern correct conductor connections. RCD checks assess relevant device operation using appropriate methods. Each answers a different question.

Operating an RCD&#x27;s user test button is not a substitute for a complete EICR. Nor does a device tripping establish the adequacy of all wiring, bonding or circuit protection. Follow the device instructions for user checks and leave professional measurements to a competent person.

## Readings support a report, not a guarantee
The report should retain relevant schedules, observations and limitations alongside its overall assessment. Ask the inspector to explain unusual results and necessary follow-up. Seeing one acceptable reading cannot rule out all hidden defects or future deterioration.

Discuss commercial EICR testing or residential EICR testing with your installation information. PAT testing addresses a separately agreed equipment scope rather than replacing fixed-installation tests.

- Keep test schedules with the report.
- Ask about context and limitations.
- Do not interpret isolated readings as a complete result.
- Use competent people for electrical testing.

## Sources and further reading

- HSE: Electrical safety at work
- IET: Further investigation and EICR classification changes in 2026General guidance for premises in England, checked on 6 November 2026. Requirements depend on your property, systems and applicable conditions. Follow competent advice, current official guidance and your local authority&#x27;s requirements.

## In this guide

- Continuity and protective conductors
- Insulation resistance
- Fault protection, polarity and RCDs
- Readings support a report, not a guarantee
## Need testing for your premises?
Greenford-based electrical and fire safety services across London.

Get a free quote 07576 584901

## Related guides
All guides 

EICR testing · 3 min read

## EICR inspection: what happens during a professional electrical assessment?
Understand the stages of a professional EICR inspection, from agreeing the scope and safe access to electrical testing, reporting and follow-up.

6 November 2026

EICR testing · 2 min read

## EICR report explained: how to read the scope, results and recommendations
Read an EICR report beyond the summary: check property details, scope, limitations, test schedules, observations and the recommended next inspection date.

6 November 2026

Electrical and fire safety compliance testing for businesses, property managers and landlords across London and Greenford.

Read our Google reviewsLeave us a review

## Services

- PAT Testing
- Commercial EICR Testing
- Residential EICR Testing
- Emergency Lighting Testing
- Fire Alarm Testing
- Fire Extinguisher Servicing
- Fire Door Inspection
- Fire Risk Assessments
- Remedial Works for Fire Compliance

## Service Areas

- Greenford
- Central London
- All London Boroughs
- West London
- North London
- South London
- East London
- Ealing
- Uxbridge
- Slough
- Watford

## Contact

- 07576 584901
- Testmasterinfo@gmail.com
- Postal address669 Greenford Road, UB6 8QL
- LinkedInOpening hours: 24/7 online enquiries

© 2026 Test Master Ltd. All rights reserved.

HomeAboutReviewsOur WorkContactPrivacy PolicyTerms &amp; ConditionsCookie Policy

Call NowFree Quote

Chat on WhatsApp